Line 46: | Line 46: | ||
{{:adc2:simulations:fsim_diff_log.png|}} | {{:adc2:simulations:fsim_diff_log.png|}} | ||
- | **remark** 1%@20Mhz@16kp = 12.7 Hz | + | **remark** : 1%@20Mhz@16kp = 12.7 Hz |
+ | |||
+ | **conclusion** : if we want to achive resonable measurement resutls for 10-bit ADC working @ 20 Mhz (and with 16k FFT len) input signal freq should not differ from ideal one more then ~1 Hz. | ||
+ | |||
+ | **conclusion 2 ** : reducing lenght of FFT (fbase is becoming larger) should relax this requirement (but also degrade precision of measurement) |