adc2:simulations:fft_freq_mismatch [2009/11/21 08:55]
szymon.kulis
adc2:simulations:fft_freq_mismatch [2019/03/08 14:08] (current)
Line 46: Line 46:
 {{:​adc2:​simulations:​fsim_diff_log.png|}} {{:​adc2:​simulations:​fsim_diff_log.png|}}
  
-**remark** 1%@20Mhz@16kp = 12.7 Hz+**remark** ​1%@20Mhz@16kp = 12.7 Hz 
 + 
 +**conclusion** : if we want to achive resonable measurement resutls for 10-bit ADC working @ 20 Mhz (and with 16k FFT len) input signal freq should not differ from ideal one more then ~1 Hz.  
 + 
 +**conclusion 2 ** : reducing lenght of FFT (fbase is becoming larger) should relax this requirement (but also degrade precision of measurement)